Melt Flow Index Tester in Tanzania

Melt Flow Index Tester in Tanzania
4 out of 5

The melt flow rate measurement helps to evaluate the property and efficiency of a high-quality plastic. The viscosity, chemical structure, etc., are checked to ensure the proper quality of the plastic materials. Presto offers the Melt Flow Index Tester in Tanzania to test the MFI of plastic resins. The device is best, simple and allows convenient testing procedures.

Presto is gaining customers reliability and trust for many years and is the best manufacturer of Melt Flow Index Tester in Tanzania. The instrument is used to test the melt flow index of the plastic granules. The device has significant in the plastic industries. The tool is equipped with a digital display to indicate the temperature of the heater with accuracy. The PID controller and RTD PT-100 sensors effectively control the heat produced by the heater. The tool complies with all the standard guidelines and is provided with a conformance certificate. The user manual is also supplied to support the end users for better understanding.

MODEL:MFI-DX
PDF Download
Contact Us

Product Description

The melt flow rate measurement helps to evaluate the property and efficiency of a high-quality plastic. The viscosity, chemical structure, etc., are checked to ensure the proper quality of the plastic materials. Presto offers the Melt Flow Index Tester in Tanzania to test the MFI of plastic resins. The device is best, simple and allows convenient testing procedures.

Presto is gaining customers reliability and trust for many years and is the best manufacturer of Melt Flow Index Tester in Tanzania. The instrument is used to test the melt flow index of the plastic granules. The device has significant in the plastic industries. The tool is equipped with a digital display to indicate the temperature of the heater with accuracy. The PID controller and RTD PT-100 sensors effectively control the heat produced by the heater. The tool complies with all the standard guidelines and is provided with a conformance certificate. The user manual is also supplied to support the end users for better understanding.

  • Temperature range is from ambient to 4000
  • Least count 0.10 C and high accuracy of ±1%.
  • The piston head diameter is 9.47 mm and heater cavity is55 mm.
  • The LED display for accurate information about the heater cavity temperature.
  • The machine has additional dead weights for additional load on the specimen. The dead weights are provided on request.
  • The RTD PT-100 sensor for precise heater temperature.
  • PID temperature for temperature control of the heater cavity.
  • The sample cutting performed both manually and automatically.
  • The instrument has 0.5 kilowatts power.
  • The optional digital weighing balance.
  • PID temperature controller is based on microcontroller.
  • Digital timer for accurate setting of sample cutting.
  • The standard accessories are also provided.

Standards

  • IS 10810-1984: Method of test for cables part 23: melt flow Index
  • ASTM D 1238-13: Standard Test method for Thermoplastic by extrusion platometer flow rates
  • IS 2530-1963 (R 2003): Methods of test for polyethylene molding materials & polyethylene compounds